Login
EuropaOwners Random Items W31_3
Advanced Search
View Slideshow (Fullscreen)

Random Items

1. BR1 2. BR3 3. W31_3 4. BR5 5. w31_breaker 6. BR6 7. BR2 8. BR4

Random Images

Cooling/demist fan 6.

Cooling/demist fan 6.

Date: 05/02/2009 Views: 7336

img0862copy

img0862copy

Date: 07/29/2007 Views: 3461

IMG_0326

IMG_0326

Date: 04/17/2005 Views: 4782

Newest Image

EAA SITE

EAA SITE

Date: 08/23/2023 Views: 726205

Most Viewed Image

EAA SITE

EAA SITE

Date: 08/23/2023 Views: 726205

W31_3

W31 3
http://aeroelectric.com/Pictures/Breakers/W31_3.jpg
". . . where robustness of the braided copper jumper wire is not meeting design goals. If the "added insulator" is not present, jumper failure causes load current to flow through the contact-spreading spring. IF the switch is used in a high current application (prop de-ice, pitot heat) then the spring smokes and folks get upset."
"The "FIX" didn't stop the wire from breaking, it only kept the secondary event from occurring. So instead of getting a broken wire followed by smoke, you only get a dead accessory. Now, I suppose the next shoe to drop will insist that some light or warning be included.
Yeah, put a paragraph in the flight manual asking the pilot to keep an eye on the ammeter lest a broken wire sneak past without notice . . . but at least we don't put smoke in the cockpit."
Note:
Here is an alternative breaker switch and pics of braid failure:
http://www.williamsairpower.com/pdf/switches.pdf
Y9-07-31

Date: 08/15/2008
Size:
Full size: 1024x768
nextlast
first previous
W31_3

Photo Properties

summary  details
Color Space Uncalibrated Date/Time Fri 15 Aug 2008 11:32:02 AM UTC
nextlast
first previous
Powered by Gallery v2.3