Login
EuropaOwners Random Items Ducati Regulator Gilles 3
Advanced Search
View Slideshow (Fullscreen)

Random Items

1. How to... 2. How to... 3. Ducati... 4. MR2510... 5. Ducati... 6. How to... 7. How to... 8. Ducati... ... 10. How to...

Random Images

IMG_0108

IMG_0108

Date: 01/01/2007 Views: 5942

FirewallPanels04

FirewallPanels04

Date: 03/11/2004 Views: 4670

DSCN6544

DSCN6544

Date: 10/25/2009 Views: 4913

Newest Image

EAA SITE

EAA SITE

Date: 08/23/2023 Views: 773374

Most Viewed Image

EAA SITE

EAA SITE

Date: 08/23/2023 Views: 773374

Ducati Regulator Gilles 3

Why no failure ?
Many homebuilders may not experience regulator failures

There are two reasons :

- Many use but one tenth of the nominal power advertised by ROTAX.

- It takes 45 min for the regulator to reach its max temperature (thermal time constant on the order of 15 min)

Cooling
With a PC type fan, the regulator heat sink thermal resistance drops to about 0.5°C/W. At sea level and nominal output, the ambient temperature needs to stay below :


125 - 80×(0.5 + 0.3) = + 61°C

Much more reasonable.

See Gilles website:
http://contrails.free.fr/elec_ducati_en.php

Date: 06/14/2010
Full size: 300x258
first previous
Ducati Regulator Gilles 3
first previous
Powered by Gallery v2.3