Login
EuropaOwners Random Items InstrumentPanel67Ann
Advanced Search
View Slideshow (Fullscreen)

Random Images

EISConnAann

EISConnAann

Date: 05/28/2004 Views: 3780

DSCN6241

DSCN6241

Date: 10/11/2009 Views: 4619

IM002995

IM002995

Date: 10/28/2007 Views: 11683

Newest Image

EAA SITE

EAA SITE

Date: 08/23/2023 Views: 704059

Most Viewed Image

EAA SITE

EAA SITE

Date: 08/23/2023 Views: 704059

InstrumentPanel67Ann

Evaluated the current (as in amperage) requirements for the aircraft. Pretty stiff. It's almost 50 amps if everything electrical is turned on. The ammeter is only rated at 45 amps and the wire feeding the 35 amp master breaker is a #10 AWG. This is only rated for 35 Amps. Looks like I have to go to a larger ammeter, heavier #8 wire (50 amps) and go to a 50 amp breaker. That or add another 35 amp breaker and split the load at the ammeter shunt. I think I'll add another breaker and split the load. Will also install a larger, 75 amp, ammeter.

Date: 09/29/2004
Full size: 640x480
InstrumentPanel67Ann

Photo Properties

summary  details
Make NIKON Model E775
Aperture Value f/2.8 Color Space Uncalibrated
Exposure Bias Value 0 EV Exposure Program Program
Flash Flash Focal Length 5.8 mm
ISO 100 Metering Mode Multi-Segment
Shutter Speed Value 0.02 sec Date/Time Wed 29 Sep 2004 05:42:50 PM UTC
IPTC: Caption
Powered by Gallery v2.3